SMALL VOLUME LONG PULSE X RAY PREIONISED XeCl LASER WITH DOUBLE DISCHARGE AND FAST FERRITE MAGNETIC SWITCH
J.M. HUEBER, M.N. KOBHIO, B.L. FONTAINE, Ph. DELAPORTE, M. SENTIS and B.M. FORESTIERIMFM-UM34 CNRS, Aix-Marseille University, 1 rue Honnorat, F-13003 Marseille, France
Abstract
Experimental results obtained with a high efficiency small volume long pulse X-Ray preionised XeCl laser with double discharge and very fast ferrite magnetic switch are presented and compared with the results given by a new XeCl laser numerical self consistant model. The model takes into account most recent kinetic data and time variation of discharge impedence and switch inductance. There is a good agreement between experiment and model on electrical and laser parameters for typical conditions.