Numéro
J. Phys. IV France
Volume 09, Numéro PR3, March 1999
Proceedings of the 9th SolarPACES International Symposium on Solar Thermal Concentrating Technologies
STCT 9
Page(s) Pr3-643 - Pr3-648
DOI https://doi.org/10.1051/jp4:19993102
Proceedings of the 9th SolarPACES International Symposium on Solar Thermal Concentrating Technologies
STCT 9

J. Phys. IV France 09 (1999) Pr3-643-Pr3-648

DOI: 10.1051/jp4:19993102

Development and test of a high flux calorimeter at DLR Cologne

U. Groer and A. Neumann

Deutsches Zentrum für Luft- und Raumfahrt e. V., Solare Energietechnik, 51170 Köln, Germany


Abstract
After an introduction into the principle of black body calorimeters the optical lay-out and the mechanical design of the DLR high flux calorimeter SUNCATCH are described. The various loss mechanism are evaluated and other important design parameter are discussed. In addition to constructional parameters the performance of the data acquisition system (DAS) highly influences the accuracy of the calorimeter. Main features of the DAS and the sensors are outlined. From a detailed error analysis of the SUNCATCH a measurement uncertainty of about ±0.5% at high fluxes can be expected. A comprehensive measurement campaign with SUNCATCH, the flux mapping system FATMES and a Kendall radiometer under flux in the DLR solar furnace is described. An excellent agreement was found between both fluxmeter with an RMS deviation of about ±1%.



© EDP Sciences 1999