Numéro |
J. Phys. IV France
Volume 04, Numéro C5, Mai 1994
3ème Congrés français d'acoustique3rd French conference on acoustics |
|
---|---|---|
Page(s) | C5-295 - C5-298 | |
DOI | https://doi.org/10.1051/jp4:1994561 |
3ème Congrés français d'acoustique
3rd French conference on acoustics
J. Phys. IV France 04 (1994) C5-295-C5-298
DOI: 10.1051/jp4:1994561
Czech Technical University, Faculty of Electrical Engineering, Department of Radioelectronics, Technická 2, 16627 Prague 6, Czech Republic
© EDP Sciences 1994
3rd French conference on acoustics
J. Phys. IV France 04 (1994) C5-295-C5-298
DOI: 10.1051/jp4:1994561
Impulse response measurement of ultrasonic transducers
F. KADLECCzech Technical University, Faculty of Electrical Engineering, Department of Radioelectronics, Technická 2, 16627 Prague 6, Czech Republic
Abstract
Digital processing of acoustic signals introduces pulses to measurement of impedances and transfer functions of ultrasonic systems. Digital impulse measurements of electroacoustic transducers described in the paper are based on comparison between the Fourier transforms of the input signals and the responses of the ultrasonic systems. Measuring signals consisting of two separate parts have been used where the power piezoelectric transducer is the input part of the system. Similarly, the output response also has two parts.