Numéro
J. Phys. IV France
Volume 01, Numéro C7, Décembre 1991
2nd International Conference
Laser M2P
Page(s) C7-567 - C7-570
DOI https://doi.org/10.1051/jp4:19917151
2nd International Conference
Laser M2P

J. Phys. IV France 01 (1991) C7-567-C7-570

DOI: 10.1051/jp4:19917151

SMALL VOLUME LONG PULSE X RAY PREIONISED XeCl LASER WITH DOUBLE DISCHARGE AND FAST FERRITE MAGNETIC SWITCH

J.M. HUEBER, M.N. KOBHIO, B.L. FONTAINE, Ph. DELAPORTE, M. SENTIS and B.M. FORESTIER

IMFM-UM34 CNRS, Aix-Marseille University, 1 rue Honnorat, F-13003 Marseille, France


Abstract
Experimental results obtained with a high efficiency small volume long pulse X-Ray preionised XeCl laser with double discharge and very fast ferrite magnetic switch are presented and compared with the results given by a new XeCl laser numerical self consistant model. The model takes into account most recent kinetic data and time variation of discharge impedence and switch inductance. There is a good agreement between experiment and model on electrical and laser parameters for typical conditions.