High-fidelity tomographic imaging reconstruction for photopyroelectric thermal wave detection equipment

A. Yarai, K. Sakamoto and T. Nakanishi

Department of Electrical Engineering and Electronics, Faculty of Engineering, Osaka Sangyo University, Daito, Osaka, Japan


Abstract
This paper describes a high-fidelity tomographic imaging reconstruction method for photopyroelectric thermal wave detection equipment. The high-fidelity is achieved through a high signal-to-noise ratio detection technique and through a new calculation algorithm. A very-smalldiameter detection metal probe tip can be used due to the high signal-to-noise ratio detection technique, increasing the spatial resolution. The calculation algorithm which considers thermal wave transmission paths along with defects achieves the high-fidelity tomographic imaging reconstruction.



© EDP Sciences 1994